Created page with "Return to The Warp Pharmacy:Software Last update: 6th November, 1995 ---- == Symptoms == Warp's LaunchPad appears in lower left of screen upon loading. == Problem ..." |
mNo edit summary |
||
Line 3: | Line 3: | ||
Last update: 6th November, 1995 | Last update: 6th November, 1995 | ||
== Symptoms == | |||
== Symptoms == | |||
Warp's LaunchPad appears in lower left of screen upon loading. | Warp's LaunchPad appears in lower left of screen upon loading. | ||
== Problem == | == Problem == | ||
After the LaunchPad has been accidentally maximized, Warp automatically places it in the lower left of the screen when OS/2 or the LaunchPad is loaded. Even if the LaunchPad is not actually maximized (which it shouldn't be) | |||
After the LaunchPad has been accidentally maximized, Warp automatically | |||
places it in the lower left of the screen when OS/2 or the LaunchPad is loaded. | |||
Even if the LaunchPad is not actually maximized (which it shouldn't be) | |||
== Procedure == | == Procedure == | ||
The only way to stop the LaunchPad from being placed on the lower left corner is to delete it (by right clicking on the LaunchPad icon or the LaunchPad itself and selecting delete) and then reopen it (by double-clicking on the desktop or rebooting). | |||
The only way to stop the LaunchPad from being placed on the lower left corner is | |||
to delete it (by right clicking on the LaunchPad icon or the LaunchPad itself and selecting | |||
delete) and then reopen it (by double-clicking on the desktop or rebooting). | |||
== Notes == | == Notes == | ||
The LaunchPad is not actually supposed to have the ability to maximize, but due to the design of the workplace shell, the LaunchPad can be caused to maximize in ways other than the normal right-clicking and selecting maximize (since that is not available). | |||
The LaunchPad is not actually supposed to have the ability to maximize, but due to the | |||
design of the workplace shell, the LaunchPad can be caused to maximize in ways other | |||
than the normal right-clicking and selecting maximize (since that is not available). | |||
''By Michael Garcia'' | |||
By | |||
Return to [[The Warp Pharmacy:Software]] | Return to [[The Warp Pharmacy:Software]] | ||
[[Category:The Warp Pharmacy]] | [[Category:The Warp Pharmacy]] |
Revision as of 21:30, 7 June 2017
Return to The Warp Pharmacy:Software
Last update: 6th November, 1995
Symptoms
Warp's LaunchPad appears in lower left of screen upon loading.
Problem
After the LaunchPad has been accidentally maximized, Warp automatically places it in the lower left of the screen when OS/2 or the LaunchPad is loaded. Even if the LaunchPad is not actually maximized (which it shouldn't be)
Procedure
The only way to stop the LaunchPad from being placed on the lower left corner is to delete it (by right clicking on the LaunchPad icon or the LaunchPad itself and selecting delete) and then reopen it (by double-clicking on the desktop or rebooting).
Notes
The LaunchPad is not actually supposed to have the ability to maximize, but due to the design of the workplace shell, the LaunchPad can be caused to maximize in ways other than the normal right-clicking and selecting maximize (since that is not available).
By Michael Garcia